The withstand voltage of aluminum substrates is a concern for many customers. The withstand voltage value of an aluminum substrate is generally closely related to the insulation layer, with a normal value of about 500 V. Aluminum substrates are used in different products with different withstand voltage requirements; some customers require a withstand voltage of 3500-4000 V, which is handled by thickening the insulation layer of the aluminum substrate. Below we describe the withstand voltage test method for aluminum substrates:
1. First, clean the workbench and put on anti-static gloves.
2. Connect the power switch of the withstand voltage tester and set the test voltage and circuit.
3. Before connecting the aluminum substrate to be tested, first confirm that the voltmeter reads "0" and that the test lamp is off, then connect the ground wire properly.
4. When pressing the start button, make sure the red probe points in a direction where there is no one, then press the start button.
5. During the test, if the withstand voltage tester makes no sound and the aluminum substrate is not broken down, burned, or discolored, the product is qualified; otherwise it is not.
6. When removing the aluminum substrate after the test, press the reset button; once the high-voltage input is confirmed to be "0", reset and take out the product.
Shenzhen Mingshihai Electronics Co., Ltd. was founded in 2010 and is a professional manufacturer of metal substrates including high-thermal-conductivity, high-power single/double-sided aluminum substrate circuit boards, thermoelectric separation copper substrate circuit boards, and copper-aluminum composite boards. The company currently has a team of more than 100 people, a factory area of over 3,000 square meters, and a monthly production capacity of more than 10,000 square meters. If you have any needs, feel free to contact our company!