In the design and manufacturing of inverters, over-current and short-circuit protection is a very important step that largely determines the safety of the inverter in actual use. If the over-current and short-circuit protection circuit fails, the inverter may burn out, so the short-circuit protection circuit has a major impact on the inverter.
To quickly understand the over-current behavior of the inverter within its short-circuit protection circuit, we first comprehensively analyze the load characteristics. Most loads in real life are impact loads, such as incandescent bulbs, whose resistance when cold is much lower than when lit; for rectifier loads such as computers and TVs, a large capacitor filter is used after AC rectification, so the inrush current is even greater. There are also inductive loads such as refrigerator motors, which require a large torque current from standstill to normal rotation, resulting in a relatively large starting current.
When the rated output power is lower than the starting power, the load cannot start. Of course, this only means the inverter can be set for long-term operating output power. At this point, the inverter would have to be sized according to the starting power, which is clearly wasteful. In practical applications, when designing the over-current and short-circuit protection circuit, we design two protection points: rated power and peak power. The peak power is usually set to 2 to 3 times the rated power. The rated power is protected against long-term operation, while the peak power generally provides protection for only a few seconds. The following is an example of an over-current and short-circuit protection circuit design:
R5 is the high-voltage current sampling resistor at the source of the full-bridge high-voltage inverter MOS tube. It can be understood as follows: the magnitude of the high-voltage current basically determines the output power, so we use R5 to detect the high-voltage current. The two comparator units of LM339 in the figure are used for over-current and short-circuit detection respectively.
First, look at the over-current protection circuit composed of IC3D and its peripheral devices. Pin 8 of IC3D sets the reference voltage, whose value is determined by the partial voltage of R33, VR4, R56, and R54: U8 = 5 × (R33 + VR4) / (R33 + VR4 + R56 + R54). When the voltage on R5 passes through the delay of R24 and C17 and exceeds the pin 8 voltage, pin 14 outputs a high level that is isolated from pin 5 of IC3B via D7. Pin 4 is for dual-battery under-voltage protection; under normal conditions the pin 5 voltage is lower than pin 4; after over-current, the pin 5 voltage is higher than pin 4, and pin 2 outputs a high level to control the shutdown of the post-stage high-voltage MOS, and it can also control the shutdown of the pre-stage MOS. The role of D8 is to positively feed back and latch pin 2 at high level under over-current, short-circuit, or battery under-voltage conditions.
The short-circuit protection point should be designed according to parameters such as the MOS tube ID, safe operating area, and circuit stray resistance. Generally, an action time within 30 microseconds while the current is within the ID is relatively safe. The principle of the IC3C short-circuit protection circuit is similar to the over-current protection circuit, but the delay is shorter. The C19 capacitance is small and the LM339 responds quickly. Short-circuit protection can shut down within a few microseconds, effectively protecting the safety of the high-voltage MOS tube.
The above is the relevant introduction to why short-circuit protection in street light aluminum substrates protects the circuit against the inverter.