2. When the number of heating components is large (more than three), a large heat-spreading plate (board) can be used. It is a special heat sink customized according to the position and height of the heating components on the PCB, or a large flat-plate heat sink designed for different component heights. The heat sink cover is attached to the component surfaces and contacts each component to dissipate heat. However, because components vary in height after mounting and soldering, the heat dissipation effect is poor. To improve it, a soft thermal interface pad is usually added to the component surfaces.
3. For equipment cooled by free convection air, it is best to integrate the circuits (or other devices) vertically or horizontally.
4. Because the resin in the copper-clad laminate has poor thermal conductivity while copper foil traces and holes are good heat conductors, increasing the residual copper ratio and improving the thermal conductivity of the holes are the main means of heat dissipation. To evaluate the heat dissipation capability of a PCB, it is necessary to calculate the equivalent thermal conductivity of the insulating substrate for PCB composite materials with different thermal conductivity values (9eq).
5. Components on the same stage light aluminum substrate should be arranged according to their heat generation and thermal zoning. Devices with low heat generation or poor heat resistance (such as small-signal transistors, small-scale integrated circuits, electrolytic capacitors, etc.) should preferably be placed at the cooling airflow inlet, while devices with high heat generation or good heat resistance (such as power transistors, large integrated circuits, etc.) should be placed at the most downstream end of the cooling airflow.
6. In the horizontal direction, high-power components should be placed as close to the board edge as possible to shorten the heat transfer path; in the vertical direction, high-power components should be placed as close to the top of the circuit board as possible to reduce their influence on the temperature of other components during operation.
7. In equipment, the heat dissipation of a stage light aluminum substrate depends mainly on airflow, so the airflow path should be studied in the design and components or stage light aluminum substrates should be arranged reasonably. Airflow tends to flow where resistance is lowest, so when placing components on a stage light aluminum substrate, avoid leaving a large open space in one area. The same issue should be noted when configuring multiple stage light aluminum substrates.
8. Temperature-sensing devices should preferably be placed in the lowest-temperature area (such as the bottom of the equipment), not on top of heating devices, and multiple devices should preferably be staggered on the horizontal plane.
9. Place the devices with the highest power consumption and the greatest heat generation near the position with the best heat dissipation. Unless a heat sink is nearby, do not place tall heating devices at the corners or edges of the board. When designing power resistors, select larger components and adjust the layout of the stage light aluminum substrate to allow sufficient heat dissipation.
10. Avoid concentrating hot spots on the stage light aluminum substrate; distribute power as evenly as possible across the stage light aluminum substrate to keep the surface temperature uniform and consistent. Strict uniform distribution is difficult to achieve in design, but areas with excessively high power density should be avoided so that hot spots do not affect the normal operation of the entire circuit.